performance |
|
|
Model |
5V |
-5V |
12V |
-12V |
15V |
-15V |
24V |
|
DC output voltage |
TP-150-U1 |
5V |
-5V |
12V |
|
|
|
|
|
TP-150-U2 |
5V |
|
12V |
-12V |
|
|
|
|
TP-150-U3 |
5V |
|
|
|
15V |
-15V |
|
|
TP-150-U4 |
5V |
|
12V |
|
|
|
24V |
|
output voltage tolerance |
TP-150-U1 |
±3% |
±6% |
±8% |
|
|
|
|
|
TP-150-U2 |
±3% |
|
±8% |
±6% |
|
|
|
|
TP-150-U3 |
±3% |
|
|
|
10%±6% |
±8% |
|
|
TP-150-U4 |
±3% |
|
±6% |
|
|
|
±8% |
|
Output current range |
TP-150-U1 |
2-20A |
0-1A |
0.4-7A |
|
|
|
|
|
TP-150-U2 |
2-20A |
|
0.4-7A |
0-1A |
|
|
|
|
TP-150-U3 |
2-20A |
|
|
|
0.4-6A |
0-1A |
|
|
TP-150-U4 |
2-20A |
|
0-1A |
|
|
|
0.4-4A |
|
Ripple & noise (MVP-P) |
TP-150-U1 |
100 |
100 |
120 |
|
|
|
|
|
TP-150-U2 |
100 |
|
120 |
100 |
|
|
|
|
TP-150-U3 |
100 |
|
|
|
150 |
100 |
|
|
TP-150-U4 |
100 |
|
100 |
|
|
|
150 |
|
output current |
TP-150-U1 |
20A |
1A |
7A |
|
|
|
|
|
TP-150-U2 |
20A |
|
7A |
1A |
|
|
|
|
TP-150-U3 |
20A |
|
|
|
6A |
1A |
|
|
TP-150-U4 |
20A |
|
1A |
|
|
|
4A |
|
efficiency |
TP-150-U1 |
75% |
|
TP-150-U2U3 |
77% |
|
TP-150-U4 |
78% |
|
Input voltage range |
90-264VAC 47-63Hz 120-370VDC |
|
Inrush current |
cold inrush current 45A/230VAC |
|
overload protection |
105%-150% output cutout, auto recovery |
|
Overvoltage protection |
5V: 5.75-6.75 shutdown |
|
temperature coefficient |
± 0.03%/ (0-50 ) |
|
startup . rise . retention time |
800ms,60ms,20ms/230VAC |
|
Withstand voltage |
Input output:2KvAC input and crust,1.5KVACoutput and crust,0.5kvAC,1 min |
|
outline dimension |
199 × 99 ×50mm |
|
safety standards |
UL 1950 |
|
EMC standard |
EN55022 class B EN61000-3-2,3 EN61000-4-2,3,4,5,6,8 11 ENV50204 |
|
|