MODEL |
FY-350-12
|
|
OUTPUT |
DC VOLTAGE |
12V |
|
RATED CURRENT |
29A |
|
CURRENT RANGE |
0 ~ 29A |
|
RATED POWER |
348W |
|
RIPPLE & NOISE (max.) |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
10 ~ 13.2V |
|
VOLTAGE TOLERANCE |
±1.0% |
|
LINE REGULATION |
±0.5% |
|
LOAD REGULATION |
±0.5% |
|
SETUP, RISE |
200ms, 50ms/230VAC at full load |
|
HOLD TIME (Typ.) |
20ms/230VAC at full load |
|
INPUT |
VOLTAGE RANGE |
180 ~ 264VAC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
|
EFFICIENCY (Typ.) |
74% |
|
AC CURRENT |
4A/230VAC |
|
INRUSH CURRENT (max.) |
COLD START 50A/230VAC |
|
LEAKAGE CURRENT |
<3.5mA / 240VAC |
|
PROTECTION |
OVER LOAD |
105 ~ 135% rated output power |
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|
OVER VOLTAGE |
|
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|
OVER TEMPERATURE |
≥80 ? output shutdown |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +60 ?(Refer to output load derating curve) |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-20 ~ +85? , 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
±0.03%/ ?(0 ~ 50? ) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
|
SAFETY & EMC
|
SAFETY STANDARDS |
UL60950-1, CB(IEC60950-1) Approved |
|
WITHSTAND VOLTAGE |
I/P-O/P:2KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
|
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
|
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
|
EMS IMMUNITY |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A |
|
OTHERS |
MTBF |
260Khrs min. MIL-HDBK-217F (25? ) |
|
DIMENSION |
240*155*65mm (L*W*H) |
|
PACKING |
|