type |
Q-120-U2 |
Q-120-U3 |
Q-120-U4 |
|
DC VOLTAGE |
5V |
-5V |
12V |
-12V |
5V |
-5V |
15V |
-15V |
5V |
12V |
-12V |
24V |
|
VOLTAGE TOLERANCE |
±2% |
±6% |
±6% |
±6% |
±2% |
±6% |
+10,-5% |
+10,-5% |
±2% |
±6% |
±6% |
±6% |
|
RATED CURRENT |
11A |
1A |
4A |
1A |
10A |
1A |
3.5A |
1A |
8A |
2A |
1A |
2A |
|
CURRENT RANGE |
2-12A |
0.2-1A |
0.5-5A |
0.2-1A |
2-12A |
0.2-1A |
0.5-5A |
0.2-1A |
2-12A |
0.2-1A |
0.2-1A |
0.2-2A |
|
RIPPLE&NOISE (MA X.) mvp-p |
80 |
80 |
120 |
120 |
80 |
80 |
150 |
150 |
80 |
120 |
120 |
180 |
|
LINE REGULATION |
±0.5% |
±1% |
±1% |
±1% |
±0.5% |
±1% |
±1% |
±1% |
±0.5% |
±1% |
±1% |
±1% |
|
LOAD REGULATION |
±0.5% |
±5% |
±5% |
±5% |
±0.5% |
±5% |
±6% |
±6% |
±0.5% |
±5% |
±5% |
±5% |
|
RATED POWER |
120W |
122.5W |
124W |
|
EFFICIENCY(Typ.) |
77% |
76% |
80% |
|
VOLTAGE ADJ.RANGE |
CH1:+10,-5% |
|
VOLTAGE RANGE |
85~132VAC/176- 264VAC 47-63Hz;240-370VDC |
|
AC CURRENT |
2.5A/115V 1.25A/230V |
|
INRUSH CURRENT(MAX.) |
cold inrushed current 35A/115V |
|
LEAKAGE CURRENT |
<3.5mA/240VAC |
|
OVERLOAD PROTECTION |
105%-135% type:output cutout:auto recovery |
|
OVERVOLTAGE PROTECTION |
115%-145% |
|
OVERTEMPERATURE PROTECTION |
...................... |
|
TEMP.COEFFICIENT |
±0.03%/ (0~50 ) |
|
SETUP.RISE,HOLD TIME |
200ms,50ms,20ms/230VAC |
|
WITHSTAND VOLTAGE |
I/P-O/P:2KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC, 1 min |
|
ISOLATED RESISTOR |
I/P-O/P,I/P-FG,O/P-FG: 100MΩ/500VDC |
|
WORKING TEMP.HUMIDITY |
-10 ~+60 ,20%~90RH |
|
DIMENSION |
199×110×50mm |
|
SAFETY STANDARDS |
CE certificated |
|
EMC |
CISPR22?EN55022? CLASSB IEC801-2-3-4 IEC555-2 |
|
|
|