performance |
Product model |
|
D-50-U5 |
D-50-U7 |
|
DC output voltage |
12V |
-12V |
24V |
-24V |
|
output voltage tolerance |
±2% |
+5%,-8% |
±2% |
±8% |
|
Output Power |
48W |
|
Ripple & noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
Line regulation |
±0.5% |
±1% |
±0.5% |
±1% |
|
Load regulation |
±0.5% |
±4% |
±0.5% |
±4% |
|
DC rate output current |
2A |
2A |
1A |
1A |
|
efficiency |
75% |
|
Input voltage range |
85-132VAC /170-264VAC,choose by switch,47-63Hz |
|
Input current |
1.3A/115V 0.65A/230V |
|
Inrush current |
cold inrush current 18A/115VAC 36A/230VAC |
|
leakage current |
< 0.5mA/240VAC |
|
overload protection |
105%-150%,Current limitation, Replacement, Auto Recovery |
|
Tem. Coeffi. |
±0.03%/ (0-50 ) |
|
Setup . rise . Holdtime |
200ms,50ms,30ms/230VAC |
|
Withstand voltage |
Input output:2KvAC input and crust,1.5KVACoutput and crust,0.5kvAC,1 min |
|
Isolated resistor |
Input output: input and crust, output and crust. 100M /500VDC |
|
outline dimension |
159 × 97×38mm |
|
safety standards |
UL1012 |
|
EMC standard |
CISPR22(EN55022)CLASSB.IEC61000-4-2,2,3,4,5 EN6100-3-2,3 |
|
|